Vortex Flow Meter

The WK-LUGB vortex flow meter measures the volume flow, standard volume flow or mass flow of gas, steam or liquid based on the Karman vortex principle.

Model: WK- LUGB
MOQ: 1PCS
Payment: Wire transfer/ Credit card
Lead Time: 5-7 days
OEM/ODM: Available

Share:

Description

WK-LUGB vortex flow meter is widely used in petroleum, chemical, metallurgy, heat, textile, paper and other industries for superheated steam, saturated steam, compressed air and general gases (oxygen, nitrogen and hydrogen, natural gas, coal gas, etc.), water and liquids (such as: water, gasoline, alcohol, benzene, etc.) measurement and control.

Nominal diameter(mm)

15、20、25,40,50,65,80,100,125,150,200,250,300,(300~1000 insertion type)

Nominal pressure(MPa)

Standard: DN15-DN200 4.0,DN250-DN300 1.6

Medium temperature(℃)

Piezoelectric:-40~150,-40~260,-40~330;Capacitive: -40~400,-40~500

Body material

1Cr18Ni9Ti,(other materials please contact before order)

Allowable vibration acceleration

Piezoelectric: 0.2g      Capacitive: 1.0~2.0g

Accuracy

±1%R,±1.5%R;insertion type: ±2.5%R,

Range ratio

1:6~1:30

Voltage

Sensor: DC +12V,DC +24V;Transmitter: DC +12V ,DC +24V;Battery-powered type: 3.6V

Output

Square wave pulse (excluding battery-powered type): high level ≥5V, low level ≤1V; current: 4~20mA

Pressure loss coefficient

Conforms to JB/T9249 standard Cd≤2.4

Explosion-proof

Intrinsically safe: ExdⅡia CT2-T5, Flame-proof type: ExdⅡCT2-T5      

Protection level

General IP65, Submersible IP68

Environmental conditions

Temperature -20℃~55℃, relative humidity 5%~90%, atmospheric pressure 86~106kPa

Applicable medium

Gases, liquids, vapours

Transmission distance

Three-wire pulse output type: ≤300m, two-wire standard current output type (4-20mA) ≤1500m; load resistance ≤750Ω;  RS485/HART≤1200m.