Electromagnetic Flow Meter

Electromagnetic flow meter is one of the most widely used industrial instruments, is a reliable and economical water flow measurement technology. There are multiple styles to choose from such as compact, split, split waterproof, battery-powered, plug-in, etc.

  • MOQ: 1PCS
  • Payment: Bank transfer/ Wire transfer
  • Lead Time: 5-7 days
  • OEM/ODM: Available
Share:

Description

It is suitable for conductive media with a conductivity greater than 5uS/cm, has a wide nominal diameter range, adapts to various actual environmental conditions, has multiple power supply methods and multiple signal outputs, adopts standard RS-485 serial communication interface, supports international common standard MODBUS-RTU communication protocol and various wireless and wired communication networking methods such as GPRS, with cumulative pulse equivalent output.

Advantage
*Excellent measurement repeatability and linearity
*Good reliability and anti-interference performance
*Good pressure resistance sealing ability
*Low pressure loss measurement tube
*High intelligentization
*Maintenance-free

Nominal diameter 15-2000mm      
Velocity range 0-10m/s      
Degree of accuracy ±0.5%R,±1%R(<DN20)      
Medium conductivity ≥5uS/cm,Actual conductivityz30uS/cm      
Nominal pressure 1.0MPa 1.6MPa 2.5MPa 4.0MPa
DN15-DN800 DN15-DN800 DN15-DN600 DN15-DN50
Environmenttemperature Sensor 0℃-+80℃ or
-25℃
-+120℃ or +70℃-+250℃
Incorporate type -10℃-+55℃
Highest mediumtemperature Incorporate type +80℃
Separated type CR chloroprene rubber liner (CR) +80℃
Polytetrafluoroethylene lining(F4) +120℃
Politef lining(F46)
Teflon(PFA) +180℃
Fluorosilicone rubber(FVMQ) +250℃
Output signal 4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max)
Cable entry size M20 x 1.5 (Standard nylon waterproof connector, optional explosion-proof metal connector)
Supply voltage 110/220VAC(100-240VAC),50Hz/60Hz:24VDC+10%
Power dissipation ≤15VA
Digital communication RS-485,Support standard Modbus-RTU protocol;GPRS
Signal electrode and theground electrode material Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum
Form of electric pole Interpolating,extrapolating electrode need to customize
Numberofelectrodes Standard configuration 3-4 eleclrodes (two measuring electrodes plus a grounding electrode)according to the caliber configuration
Flange Standard Conform to the international GB9119(customize according to customer's demand)
Connecting flange material Standard carbon steel and stainless steel are needed to be customized
Grounding ring material Stainless steel, and stainless steel that contains molybdenum, etc.
DN15-DN450 Stainless steel 1Cr18Ni9Ti(Ordinary austenitic stainless steel SUS321)
Housing material Standard carbon steel and stainless steel are needed to be customized
Level of protection Separate body-type IP68、IP65
Interval/wire length Incorporate type IP65
(Separate body-style) 10m standard configuration connecting line,optional 15m.20m,25m, 30m.

Electromagnetic flow meter can be widely used in petroleum, chemical, iron and steel, food, electric power, paper making, metallurgy, water supply and drainage, petrochemical, medical, environmental protection, and other industries in the conductive liquid flow measurement.