Single/ double Flange Level Transmitter

Single/double flange liquid level transmitters are simple in structure, easy to install, and extremely reliable; they are widely used and suitable for high temperature, strong corrosion and other media.

  • Model: WK-3351LT
  • MOQ: 1PCS
  • Payment: Bank transfer/ Wire transfer
  • Lead Time: 5-7 days
  • OEM/ODM: Available
Share:

Description

The WK3351LT flange level transmitter is a new type of transmitter produced by our company with the introduction of advanced foreign technology and equipment. Key raw materials, components and parts are imported. The whole machine has been strictly assembled and tested. The flange type liquid level transmitter has the characteristics of advanced design principle, complete varieties and specifications, and easy installation and use.

Advantage
1. 0.075% high accuracy;
2. The range and zero point are externally continuously adjustable;
3. Adjustable damping and high pressure resistance;
4. No mechanical moving parts, good stability,
5. Automatic fault diagnosis and less maintenance;
6. Various diaphragm materials that contact the medium are available;
7. Two-wire system 4-20mA, complies with NAMIR NE43 specification, superimposed digital signals (Hart protocol).

Performance Parameters

Measuring medium

Gas, vapour, liquid

Accuracy

±0.075%, ±0.1%, ±0.2% (including linearity, return and repeatability from zero)

Stability

±0.2%/years

Power supply

10 to 36V DC (24V DC recommended)

Reference accuracy of adjustable range

If TD>10 (TD= Maximum range / Adjustable range ) ±(0.075×TD)%

Ambient temperature

-40℃ ~85

Measuring medium temperature

-40℃~400℃

Storage temperature

-40°C ~85°C

Display

LCD, OLED

Display display module temperature

-20℃ ~ 70℃ (LCD), -40℃ ~ 80℃ (OLED)

physical parameter

Measuring diaphragms

316L, Hastelloy C, tantalum, titanium, nickel, Monel, dual phase steel, PFA, gold plating

Process connections

Stainless steel 304, 316L

Filling fluid

Silicone oil, fluorine oil, etc.

Transmitter housing

Aluminium alloy, epoxy resin sprayed on the outside.

Housing sealing ring

Nitrile rubber

Nameplate

Stainless steel 304

Shell protection grade

IP67

Explosion-proof grade

Exd Ⅱ CT6 Gb, Exia Ⅱ CT6 Ga

Single and double French differential pressure level gauges consist of a differential pressure transmitter, a capillary tube and a flange with a sealing diaphragm. The role of the sealing diaphragm is to prevent the medium in the pipeline from directly entering the differential pressure transmitter. It is connected to the transmitter by a capillary tube filled with liquid (generally silicone oil is used). When the diaphragm is pressed, it will cause slight deformation, and the deformation displacement or frequency is transmitted to the transmitter through the liquid in the capillary tube, which is processed by the transmitter and converted into an output signal. The two pressures of the medium to be measured pass into the high and low pressure chambers, act on the isolation diaphragms on both sides of the delta element (i.e., the sensitive element), and are transferred to both sides of the measuring diaphragm through the isolation diaphragms and the filling liquid in the element.

The measuring diaphragm and the electrodes on both sides form a capacitor. When the pressures on both sides are inconsistent, the measuring diaphragm is displaced, and the displacement is proportional to the pressure difference. Therefore, the capacitances on both sides are unequal, and are converted into signals proportional to the pressure through the oscillation and demodulation links.